咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >Radiometric cross-calibration ... 收藏

Radiometric cross-calibration of the CBERS-02 CCD camera with the TERRA MODIS

Radiometric cross-calibration of the CBERS-02 CCD camera with the TERRA MODIS

作     者:LI Xiaoying1,2,3, GU Xingfa1,3,4, MIN Xiangjun5, YU Tao1,3, FU Qiaoyan5, ZHANG Yong1,2,3 & LI Xiaowen1,3 1. State Key Laboratory of Remote Sensing Science, Jointly Sponsored by the Institute of Remote Sensing Applications of Chinese Academy of Sciences and Beijing Normal University, Beijing 100101, China 2. Graduate University of Chinese Academy of Sciences, Beijing 100039, China 3. The Center for National Spaceborne Demonstration, Beijing 100101, China 4. Institut National de la Recherche Agronomique, Climat Sol Environnement, 84914 Avignon, France 5. China Center for Resource Satellite Data and Application, Beijing 100830, China 

作者机构:State Key Laboratory of Remote Sensing Science Beijing Normal University Chinese Academy of Sciences Beijing 100101 China Graduate University Chinese Academy of Sciences Beijing 100039 China Center for National Spaceborne Demonstration Beijing 100101 China Institut National de la Recherche Agronomique Climat Sol Environnement 84914 Avignon France China Center for Resource Satellite Data and Application Beijing 100830 China 

出 版 物:《Science China(Technological Sciences)》 (中国科学(技术科学英文版))

年 卷 期:2005年第48卷第S2期

页      面:44-60页

核心收录:

学科分类:0810[工学-信息与通信工程] 1304[艺术学-美术学] 13[艺术学] 08[工学] 0804[工学-仪器科学与技术] 0805[工学-材料科学与工程(可授工学、理学学位)] 0802[工学-机械工程] 0702[理学-物理学] 0812[工学-计算机科学与技术(可授工学、理学学位)] 

主  题:CBERS-02 CCD camera cross-calibration the spectral band matching factors. 

摘      要:For the application of the CCD camera, the most important payload on CBERS-02, the key is to provide long-term stable radiometric calibration coefficients. Although the vicarious calibration had been proved successful, it had its limitations such as test site requirement and unsuitable for historical data. Cross-calibration is one of the alternative methods, but it needs synchro surface spectrum to achieve spectral band matching factors. Our effort is to probe the influences on these factors. Simulations with a lot of surface spectrum showed that the factors changed with the viewing geometry, atmospheric condition and surface targets. However, simulating with the same viewing geometry and atmospheric condition, the spectral band matching factors of the same or similar surface targets’ spectrum acquired from different dates and different places would like to be consistent to each other within 1%―5%. Thus, the synchro measurement data can be substituted by the same or similar target from other source. Based on this method, using the MODIS as the reference, the cross-calibration was performed for CCD camera. The research demonstrated that the traditional method with single calibration site was inappropriate for CCD camera, since the offsets for its four spectral bands were not zeros. With four calibration sites, these offsets were obtained. And the camera was detected to degrade with dates based on four times of cross-calibrations.

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分