文献详情 >A rapid easy-to-perform solid ... 收藏

A rapid easy-to-perform solid phase digoxin radioimmunoassay

A rapid easy-to-perform solid phase digoxin radioimmunoassay

作     者:Li Bin Zhou Met-Ying Liu Fang-Yan Wang Met-Di (Shanghai Institute of Nuclear Research, the Chinese Academy of Sciences, Shanghai 201800) 

出 版 物:《Nuclear Science and Techniques》 (核技术(英文))

年 卷 期:1998年第9卷第4期

页      面:251-253页

核心收录:

学科分类:0831[工学-生物医学工程(可授工学、理学、医学学位)] 100207[医学-影像医学与核医学] 1006[医学-中西医结合] 1002[医学-临床医学] 1001[医学-基础医学(可授医学、理学学位)] 08[工学] 1010[医学-医学技术(可授医学、理学学位)] 100106[医学-放射医学] 100602[医学-中西医结合临床] 10[医学] 

主  题:血液地谷新 形成 光致发光 监测 

摘      要:A solid-phase-radioimmunoassay (SPRIA) for the monitoring of blood digoxinlevel has been developed, in which a secondary antibody-coated polystyrene tubes are *** noval method seems to be simple to use and only takes about an half hour. The standardcurve is linear from 0.25 to 4 μg/L. The sensitivity of the detection is 0.1 μg/L. Reproducibilitystudies with 3 control sera of 0.5-2.5 μg/L give illtraassay CV 5% and interassay CV 10%.The specimens are measured and compared with those of the conventional radioimmunoassayand the values are well correlated (r=0.96, Y=1.022X+0.04 μg/L).