咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >Comparison of dynamic defocus ... 收藏

Comparison of dynamic defocus curve Checkfor updates on cataract patients implanting extended depth of focus and monofocal intraocular

作     者:Tingyi Wu Yuexin Wang jiazhi Yu Xiaotong Ren Yuanting Li Weigiang Qiu Xuemin Li 

作者机构:Department of OphthalmologyPeking University Third Hospital49 North Garden RoadHaidian DistrictBeijing 100191People's Republic of China Bejing Key Laboratory of Restoration of Damaged Ocular NervePekingUniversity Third HospitalBeijingPeople's Republic of China Peking University Health Science CenterBeijingPeople's Republicof China. 

出 版 物:《Eye and Vision》 (眼视光学杂志(英文))

年 卷 期:2024年第10卷第4期

页      面:32-40页

核心收录:

学科分类:08[工学] 0812[工学-计算机科学与技术(可授工学、理学学位)] 

基  金:This work was supported by Bejing Municipal Science and Technology Commission(Grant No.7202229) Peking University Medicine Fund of Fostering Young Scholars'Scientific&Technological Innovation(Grant No.BMU2022PYB022) 

主  题:Dynamic defocus curve Age-related cataract Extended depth-of-focus intraocular lens Monofocal intraocularlens 

摘      要:Background:The aim of the study was to compare the dynamic defocus curve on patients post-implantation of the extended depth-of-focus(EDOF)and monofocal intraocular lens(IOL).Methods:A total of 62 age-related cataract patients receiving phacoemulsification with implantation of TECNIS Symfony(ZXRoO)or monofocal IOLs were *** binocular static and dynamic defocus curves with corrected distance visual acuity were evaluated at one month ***:The ZXR00 group achieved signifcantly better intermediate(P=0.044)and near(P=0.017)visual acuity(VA)than the monofocal *** groups had similar uncorrected and corrected distance VA(P0.05,respectively).The dynamic defocus curve revealed a smoother decline from 0.0 D to-2.0 D in the ZXRo0 *** dynamic VA in the ZXR00 group was significantly better(P0.05)except at 0.0 D(P=0.724)and-0.5 D(P=0.176).The area under the curve(P=0.002)and corrected dynamic vision accommodation(P=0.001)derived from the dynamic defocus curves were better in the ZxRoo group.A positive correlation was observed between defocused dynamic and static VA in both groups(P0.001).Multiple linear regression analysis indicated that defocused static VA and cor-rected dynamic vision accommodation were significant influential factors for the defocused dynamic VA from-1.0 D to-3.0 D(P0.05).Conclusions:The EDOF IOL provided similar distant vision,better intermediate and near vision,and a better overall dynamic defocus curve than the monofocal *** dynamic defocus curve may be comprehensively applied to evaluate the all-distance dynamic visual performance post-cataract surgery.

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分