咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >Design and performance evaluat... 收藏

Design and performance evaluation of a large field-of-view dual-particle time-encoded imager based on a depth-of-interaction detector

作     者:Dong Zhao Xu-Wen Liang Ping-Kun Cai Wei Cheng Wen-Bao Jia Da-Qian Hei Qing Shan Yong-Sheng Ling Chao Shi Dong Zhao;Xu-Wen Liang;Ping-Kun Cai;Wei Cheng;Wen-Bao Jia;Da-Qian Hei;Qing Shan;Yong-Sheng Ling;Chao Shi

作者机构:Department of Nuclear Science and TechnologyNanjing University of Aeronautics and AstronauticsNanjing 211106China Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education InstitutionsSuzhou 215000China School of Nuclear Science and TechnologyLanzhou UniversityLanzhou 730000China 

出 版 物:《Nuclear Science and Techniques》 (核技术(英文))

年 卷 期:2024年第35卷第4期

页      面:1-14页

核心收录:

学科分类:082704[工学-辐射防护及环境保护] 08[工学] 080203[工学-机械设计及理论] 0827[工学-核科学与技术] 0802[工学-机械工程] 0702[理学-物理学] 

基  金:supported by the National Natural Science Foundation of China(Nos.11975121,12205131) the Fundamental Research Funds for the Central Universities(No.lzujbky-2021-sp58) the Postgraduate Research&Practice Innovation Program of Jiangsu Province(No.KYCX22_0354)。 

主  题:Time-encoded imager Depth-of-interaction detector Dual-particle imaging Hotspot imaging 

摘      要:Time-encoded imaging is useful for identifying potential special nuclear materials and other radioactive sources at a distance.In this study,a large field-of-view time-encoded imager was developed for gamma-ray and neutron source hotspot imaging based on a depth-of-interaction(DOI)detector.The imager primarily consists of a DOI detector system and a rotary dual-layer cylindrical coded mask.An EJ276 plastic scintillator coupled with two SiPMs was designed as the DOI detector to increase the field of view and improve the imager performance.The difference in signal time at both ends and the log of the signal amplitude ratio were used to calculate the interaction position resolution.The position resolution of the DOI detector was calibrated using a collimated Cs-137 source,and the full width at half maximum of the reconstruction position of the Gaussian fitting curve was approximately 4.4 cm.The DOI detector can be arbitrarily divided into several units to independently reconstruct the source distribution images.The unit length was optimized via Am-Be source-location experiments.A multidetector filtering method is proposed for image denoising.This method can effectively reduce image noise caused by poor DOI detector position resolution.The vertical field of view of the imager was(-55°,55°)when the detector was placed in the center of the coded mask.A DT neutron source at 20 m standoff could be located within 2400 s with an angular resolution of 3.5°.

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分