文献详情 >Simulation of roof snow loads ... 收藏

Simulation of roof snow loads based on a multi-layer snowmelt model:Impact of building heat transfer

作     者:Xuanyi Zhou Heng Chen Yue Wu Tiange Zhang Xuanyi Zhou;Heng Chen;Yue Wu;Tiange Zhang

作者机构:State Key Laboratory of Disaster Reduction in Civil EngineeringTongji UniversityShanghai200092China 

出 版 物:《Building Simulation》 (建筑模拟(英文))

年 卷 期:2024年第17卷第6期

页      面:907-932页

核心收录:

学科分类:07[理学] 0701[理学-数学] 070101[理学-基础数学] 

基  金:the National Natural Science Foundation of China(52078380) 

主  题:snowmelt model roof snow load building heat transfer thermal coefficient load code 

摘      要:To investigate the impact of building heat transfer on roof snow loads,roof snow loads and snow load thermal coefficients from 61 Chinese sites over a period of 50 years are simulated based on basic meteorological data such as temperature,humidity,wind speed,and precipitation,and a multi-layer snowmelt model considering the building heat ***,the accuracy of the multi-layer snowmelt model is validated using the data of observed ground snow load and roof snow melting *** relationship between meteorological conditions,snow cover characteristics,and thermal coefficients of snow loads in three representative sites is then ***,the characteristics of thermal coefficients in each zone are analyzed by combining them with the statistical results of meteorological data from 1960 to 2010,and the equations of thermal coefficients in different zones on indoor temperatures and roof heat transfer coefficients are fitted ***,the equations in this paper are compared with the thermal coefficients in the main snow load *** results indicate that the snowmelt model using basic meteorological data can effectively provide samples of roof snow *** the cold zone where the snow cover lasts for a long time and does not melt easily,the thermal coefficients of the snow loads on the heating buildings are lower than those in the warm zone due to the long-term influence of the heat from inside the *** coefficients are negatively correlated with indoor temperatures and roof heat transfer *** the indoor temperature is too low or the roof insulation is good,the roof snow load may exceed the ground snow *** thermal coefficients for heated buildings in the main snow load codes are more conservative than those calculated in this paper,and the thermal coefficients for buildings with lower indoor temperatures tend to be smaller.

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分