Trans-Frame Aortic Regurgitation of New-Generation Aortic Bioprosthesis
Trans-Frame Aortic Regurgitation of New-Generation Aortic Bioprosthesis作者机构:Division of Cardiothoracic Surgery New York-Presbyterian Hospital Columbia University Medical Center New York USA Division of Cardiothoracic Anesthesia New York-Presbyterian Hospital Columbia University Irving Medical Center New York USA Division of Cardiothoracic Surgery Abbott Northwestern Hospital Minneapolis Heart Institute Minneapolis USA
出 版 物:《World Journal of Cardiovascular Surgery》 (心血管外科国际期刊(英文))
年 卷 期:2024年第14卷第4期
页 面:41-44页
学科分类:1002[医学-临床医学] 100201[医学-内科学(含:心血管病、血液病、呼吸系病、消化系病、内分泌与代谢病、肾病、风湿病、传染病)] 10[医学]
主 题:Aortic Valve Replacement Bicuspid Aortic Valve Paravalvular Leak
摘 要:A widely used aortic valve bioprosthesis is susceptible to regurgitation between the sewing ring and the frame of the valve due to its relatively thin fabric coverage. In some cases this leak has been shown to resolve with administration of protamine, however, tension on this area from annular sutures placed in an asymmetric bicuspid valve annulus may exacerbate the defect.