咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >Dynamic ageing research of cro... 收藏

Dynamic ageing research of cross‐linked polyethylene cable insulation based on temporal‐spatial dimension under combined electro‐thermal effect

作     者:Yifeng Zhao Yue Xie Yu Zhao Jiasheng Huang Xinghui Fan Yangyang Nie Gang Liu Yifeng Zhao;Yue Xie;Yu Zhao;Jiasheng Huang;Xinghui Fan;Yangyang Nie;Gang Liu

作者机构:School of Electric Power EngineeringSouth China University of TechnologyGuangzhouChina School of AutomationGuangdong Polytechnic Normal UniversityGuangzhouChina State Key Laboratory of Nuclear Power Safety Monitoring Technology and EquipmentShenzhenChina Transmission Management OfficeGuangzhou Power Supply BureauGuangzhouChina 

出 版 物:《High Voltage》 (高电压(英文))

年 卷 期:2023年第8卷第5期

页      面:1067-1081页

核心收录:

学科分类:08[工学] 0805[工学-材料科学与工程(可授工学、理学学位)] 0703[理学-化学] 0811[工学-控制科学与工程] 

基  金:2021 opening project of State Key Laboratory of nuclear power safety monitoring technology and equipment,Grant/Award Number:K‐A2021.425 Project of Guangdong key laboratory of Clean energy technology,Grant/Award Number:2008A060301002。 

主  题:dimension insulation effect 

摘      要:Dynamic ageing process of cross‐linked polyethylene(XLPE)cable insulation under combined electro‐thermal effect is investigated by the construction of theoretical analysis model and the practice of operation‐simulated ageing test.Firstly,theoretical analysis model is constructed from time and spatial dimensions.From the time dimension,in the light of the impeding trend of internal stress to external stress,the XLPE ageing process of Steady state‐Transition state‐Steady state(STS)is proposed to illustrate the dynamic ageing process of XLPE.From the spatial dimension,the insulation is divided into three scales to quantify the ageing.Secondly,to practice the theoretical analysis model,an operation‐simulated ageing test was conducted on two high voltage alternating current cables with service years of 15 and 30 for 540 days.Subsequently,relevant diagnostic measurements were applied to analyse the influence of physicochemical characteristics on the dielectric and heat transfer performances of the cables.The results show that the degradation of the actual operating cable is an extremely slow process.On the one hand,the response in physical changes of morphology counterbalances the external stress,maintaining the stability.On the other hand,once the chemical changes occur,negative feedback mechanism tends to impede the occurrence of further degradation by regulating fields distribution.

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分