Analysing light pipe two-side aperture in dense population housing to improve the visual and thermal condition
作者机构:Department of ArchitectureFaculty of EngineeringUniversitas IndonesiaKampus UIDepok16424Indonesia Applied Heat Transfer Research GroupDepartment of Mechanical EngineeringUniversitas IndonesiaKampus UIDepok16424Indonesia
出 版 物:《Energy and Built Environment》 (能源与人工环境(英文))
年 卷 期:2024年第5卷第5期
页 面:787-799页
核心收录:
学科分类:080702[工学-热能工程] 08[工学] 0807[工学-动力工程及工程热物理]
基 金:funded by the Directorate of Research and De-velopment Universitas Indonesia under Hibah PUTI 2022 (grant no.NKB-332/UN2.RST/HKP.05.00/2022)
主 题:Daylight Light pipe two aperture Densely populated urban kampung Housing Hot-humid climates
摘 要:Daylight is one of the essential criteria for decent ***,in an urban kampung,access to daylight is limited due to the high-density population in urban Kampung *** study aims to improve the visual and thermal conditions by modifying the aperture of the light pipe based on visual daylight distribution,illuminance level,and thermal conditions in multi-storey houses in hot-humid *** pipe was developed experi-mentally through the simulation model to investigate the performance and impact on the visual and thermal conditions like operational temperature and RH in densely populated Kampung Kota without vertical *** to the results,the two-aperture light pipe residential space enhanced the current situation but did not fulfill the *** two aperture light pipe visually improved daylight distribution by 1.05%-31.36%and illumination level by 8.4%-14.8%.We also found that light pipe also impacts thermal conditions with a 10.92%RH reduction while at the same time increasing temperature up to 10.57%.Therefore,it can be concluded that a two-aperture light pipe has the potential to be applied to actual conditions in hot-humid climates.