文献详情 >Breath-by-breath measurement o... 收藏

Breath-by-breath measurement of exhaled ammonia by acetonemodifier positive photoionization ion mobility spectrometry via online dilution and purging sampling

作     者:Lu Wang Dandan Jiang Lei Hua Chuang Chen Dongming Li Weiguo Wang Yiqian Xu Qimu Yang Haiyang Li Song Leng Lu Wang;Dandan Jiang;Lei Hua;Chuang Chen;Dongming Li;Weiguo Wang;Yiqian Xu;Qimu Yang;Haiyang Li;Song Leng

作者机构:CAS Key Laboratory of Separation Science for Analytical ChemistryDalian Institute of Chemical PhysicsChinese Academy of SciencesDalian116023China Health Management CenterThe Second Affiliated Hospital of Dalian Medical UniversityDalian116023China University of Chinese Academy of SciencesBeijing100049China Dalian Key Laboratory for Online Analytical InstrumentationDalian116023China Dalian Engineering Research Center of Breath Diagnostic TechnologyDalian116023China 

出 版 物:《Journal of Pharmaceutical Analysis》 (药物分析学报(英文版))

年 卷 期:2023年第13卷第4期

页      面:412-420页

核心收录:

学科分类:1007[医学-药学(可授医学、理学学位)] 1006[医学-中西医结合] 10[医学] 100602[医学-中西医结合临床] 

基  金:This work was supported by the National Natural Science Foundation of China(Grant Nos.:22027804,21974141,and 21904125) Natural Science Foundation of Liaoning Province(Grant Nos.:2022-MS-019 and 2022-MS-016) Science and Technology Innovation Foundation of Dalian(Grant No.:2022JJ13SN096) Dalian Institute of Chemical Physics(Grant Nos.:DICP I202141 and DICP I202144) 1+X Program for Large Cohort Study-Clinical Research Incubation Project,The Second Hospital of Dalian Medical University(Project No.:2022DXDL01). 

主  题:Photoionization ion mobility spectrometry Acetone modifier Exhaled ammonia Breath analysis 

摘      要:Exhaled ammonia(NH_(3))is an essential noninvasive biomarker for disease diagnosis.In this study,an acetone-modifier positive photoionization ion mobility spectrometry(AM-PIMS)method was developed for accurate qualitative and quantitative analysis of exhaled NH_(3)with high selectivity and sensitivity.Acetone was introduced into the drift tube along with the drift gas as a modifier,and the characteristic NH_(3)product ion peak of(C_(3)H_(6)O)_(4)NH_(4)^(+)(K_(0)=1.45 cm^(2)/V·s)was obtained through the ion-molecule reaction with acetone reactant ions(C_(3)H_(6)O)_(2)H^(+)(K_(0)=1.87 cm^(2)/V·s),which significantly increased the peak-to-peak resolution and improved the accuracy of exhaled NH_(3)qualitative identification.Moreover,the interference of high humidity and the memory effect of NH_(3)molecules were significantly reduced via online dilution and purging sampling,thus realizing breath-by-breath measurement.As a result,a wide quantitative range of 5.87-140.92μmol/L with a response time of 40 ms was achieved,and the exhaled NH_(3)profile could be synchronized with the concentration curve of exhaled CO_(2).Finally,the analytical capacity of AM-PIMS was demonstrated by measuring the exhaled NH_(3)of healthy subjects,demonstrating its great potential for clinical disease diagnosis.