咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >Determination of the sensible ... 收藏

Determination of the sensible heat effectiveness and pressure loss of a rotary regenerative heat exchanger using CFD

作     者:Vladimír Zmrhal Petr Zelenský Jindřich Boháč Martin Barták Miroslav Kučera Roman Vavřička Vladimír Zmrhal;Petr Zelenský;Jindřich Boháč;Martin Barták;Miroslav Kučera;Roman Vavřička

作者机构:Faculty of Mechanical EngineeringDepartment of Environmental EngineeringCzech Technical University in PragueTechnická416000Prague 6Czech Republic 

出 版 物:《Building Simulation》 (建筑模拟(英文))

年 卷 期:2023年第16卷第6期

页      面:869-887页

核心收录:

学科分类:07[理学] 0807[工学-动力工程及工程热物理] 070303[理学-有机化学] 0703[理学-化学] 0802[工学-机械工程] 0801[工学-力学(可授工学、理学学位)] 0812[工学-计算机科学与技术(可授工学、理学学位)] 

基  金:funding from the Technology Agency of the Czech Republic  under the programme TACR Theta 

主  题:rotary heat exchanger heat wheel microchannel heat recovery sensible effectiveness pressureloss computer fluid dynamics experiment 

摘      要:The paper presents a new method to determine the sensible effectiveness and pressure loss of rotary regenerative heat exchangers using computational fluid dynamics(CFD).It is based on CFD simulations of a single thermal wheel microchannel with a small cross-sectional area and thin walls,with cyclic inlet and outlet boundary conditions.Two unique measurement set-ups were designed and built for the experimental measurement of the heat exchanger characteristics.Five different types of thermal wheels were manufactured,measured,and simulated in ANSYS Fluent.All wheels achieve an effectiveness greater than 73%under certain(air flow)conditions,which is the minimum effectiveness required by Ecodesign(in the EU).For the examined exchangers,the effectiveness ranges from 66.5%to 83.3%,depending on the boundary conditions and geometric parameters of the rotors.The highest sensible effectiveness is achieved by heat exchangers with the largest heat exchange surface Ac;on the other hand,these wheels have the largest pressure loss.The paper discusses the use of a simplifiedε-NTU correlation model for the HVAC systems(typically C*=1).The correlation model and CFD results were compared and found to be different from each other.The results of the CFD simulation were compared with measurements to prove that the proposed simulation method can predict the behaviour of the real heat exchanger as a whole.It was demonstrated that the sensible effectiveness and pressure loss of the rotary heat exchanger predicted by the CFD simulations correspond well to the measured values within the measurement uncertainty±1.3%.The proposed method can be used for the comparison of different rotary regenerative heat exchangers before their manufacturing and for verification that they meet the EU Ecodesign requirements set by the current legislation.It reduces the cost of the initial optimisation and testing of new designs.

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分