Quadrupole-Linear Ion Trap Tandem Mass Spectrometry System for Clinical Biomarker Analysis
Quadrupole-Linear Ion Trap Tandem Mass Spectrometry System for Clinical Biomarker Analysis作者机构:Technology Innovation Center of Mass Spectrometry for State Market RegulationCenter for Advanced Measurement ScienceNational Institute of MetrologyBeijing 100029China College of Instrument Science and Electrical EngineeringJilin UniversityChangchun 130026China
出 版 物:《Engineering》 (工程(英文))
年 卷 期:2022年第16卷第9期
页 面:56-64页
核心收录:
学科分类:081704[工学-应用化学] 07[理学] 08[工学] 0817[工学-化学工程与技术] 1010[医学-医学技术(可授医学、理学学位)] 070302[理学-分析化学] 0703[理学-化学] 10[医学]
基 金:financially supported by the National Key R&D Program of China(2018YFF0212503,2019YFF0216303,and 2016YFF0200502) the National Natural Science Foundation of China(21927812) the Research Project of the National Institute of Metrology(AKY1934)
主 题:Linear ion trap Quadrupole Space charge effect Collision-induced dissociation Biomarker
摘 要:The accurate and efficient measurement of small molecule disease markers for clinical diagnosis is of great *** this study,a quadrupole-linear ion trap(Q-LIT)tandem mass spectrometer was designed and built in our *** precursor ions were first selected in the quadrupole,and then injected,trapped,and fragmented simultaneously in the linear ion trap(LIT)to reduce the space charge effect,enrich the target product ions,and promote *** targeted analytes were measured with selected reaction monitoring using a positive scan mode with electrospray ionization(ESI).Ions with a mass-to-charge ratio(m/z)ranging from 195 to 2022 were *** scanning at 1218amu.s^(-1),unit resolution and an accuracy of higher than m/z 0.28 was obtained for m/z up to *** dimensionless Mathieu parameter(q)value used in this study was 0.40 for collision-induced dissociation(CID),which was activated by resonance *** an overall CID efficiency of 64%was achieved(activation time,50 ms).Guanidinoacetic acid(GAA)and creatine(CRE)were used as model compounds for small molecule clinical *** limits of quantification were 1.0 and 0.2 nmol.L^(-1)for GAA and CRE,respectively.A total of 77 actual samples were successfully analyzed by the home-built ESI-Q-LIT tandem mass spectrometry *** developed method can reduce matrix interference,minimize space charge effects,and avoid the chromatographic separation of complex samples to simplify the pretreatment *** novel Q-LIT system is expected to be a good candidate for the determination of biomarkers in clinical diagnosis and therapeutics.