Performance of Dexcom G5 and FreeStyle Libre sensors tested simultaneously in people with type 1 or 2 diabetes and advanced chronic kidney disease

作     者:Arndís FinnaÓlafsdóttir Mervi Andelin Aso Saeed Sheyda Sofizadeh Hussein Hamoodi Per-Anders Jansson Marcus Lind 

作者机构:Department of MedicineNU-Hospital GroupUddevallaSweden Department of Molecular and Clinical MedicineInstitute of MedicineSahlgrenska AcademyUniversity of GothenburgGöteborgSweden Department of NephrologyGothenburg UniversitySahlgrenska AcademyInstitute Internal MedicineGöteborgSweden Statistiska KonsultgruppenGöteborgSweden Wallenberg LaboratoryDepartment of Molecular and Clinical MedicineInstitute of MedicineSahlgrenska AcademyUniversity of GothenburgGöteborgSweden 

出 版 物:《World Journal of Clinical Cases》 (世界临床病例杂志)

年 卷 期:2022年第10卷第22期

页      面:7794-7807页

核心收录:

学科分类:1002[医学-临床医学] 100210[医学-外科学(含:普外、骨外、泌尿外、胸心外、神外、整形、烧伤、野战外)] 100201[医学-内科学(含:心血管病、血液病、呼吸系病、消化系病、内分泌与代谢病、肾病、风湿病、传染病)] 10[医学] 

基  金:Bayer Sanofi Boehringer Ingelheim Novo Nordisk 

主  题:Type 1 diabetes Type 2 diabetes Chronic kidney disease Continuous glucose monitoring Accuracy Mean absolute relative difference 

摘      要:BACKGROUND Advanced chronic kidney disease(CKD) is a common complication for people with type 1 and 2 diabetes and can often lead to glucose instability. Continuous glucose monitoring(CGM) helps users monitor and stabilize their glucose levels. To date, CGM and intermittent scanning CGM are only approved for people with diabetes but not for those with advanced *** To compare the performance of Dexcom G5 and FreeStyle Libre sensors in adults with type 1 or 2 diabetes and advanced *** This was a non-randomized clinical trial that took place in two outpatient clinics in western Sweden. All patients with type 1 or 2 diabetes and an estimated glomerular filtration rate(eGFR) of 30 mL/min per 1.73 m^(2) were invited to participate. Forty patients(full analysis set = 33) carried the Dexcom G5 sensor for 7 d and FreeStyle Libre sensor for 14 d simultaneously. For referencing capillary blood glucose(SMBG) was measured with a high accuracy glucose meter(HemoCue®) during the study period. At the end of the study, all patients were asked to answer a questionnaire on their experience using the *** The mean age was 64.1(range 41-77) years, hemoglobin A1 c was 7.0% [standard deviation(SD) 3.2], and diabetes duration was 28.5(SD 14.7) years. A total of 27.5% of the study population was on hemodialysis and 22.5% on peritoneal dialysis. The mean absolute relative difference for Dexcom G5 vs SMBG was significantly lower than that for FreeStyle Libre vs SMBG [15.2%(SD 12.2) vs 20.9%(SD 8.6)], with a mean difference of 5.72 [95% confidence interval(CI): 2.11-9.32;P = 0.0036]. The mean absolute difference was also significantly lower for Dexcom G5 than for FreeStyle Libre, 1.21 mmol/L(SD 0.78) and 1.76 mmol/L(SD 0.78), with a mean diffrenec of 0.55(95%CI: 0.27-0.83;P = 0.0004).The mean difference(MD) was-0.107 mmol/L and-1.10 mmol/L(P = 0.0002), respectively. In all, 66% of FreeStyle Libre values were in the no risk zone on the surveillance error grid compared t