咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >Preoperative Intra-Aortic Ball... 收藏

Preoperative Intra-Aortic Balloon Counterpulsation in Coronary Artery Bypass Graft Patients with Severe Left Ventricular Dysfunction

Preoperative Intra-Aortic Balloon Counterpulsation in Coronary Artery Bypass Graft Patients with Severe Left Ventricular Dysfunction

作     者:Andrea Cristina Oliveira Freitas Danilo B. Gurian Wladmir F. Saporito Leandro N. Machado Louise Horiuti Adilson C. Pires Andrea Cristina Oliveira Freitas;Danilo B. Gurian;Wladmir F. Saporito;Leandro N. Machado;Louise Horiuti;Adilson C. Pires

作者机构:Rua Dr. Henrique Calderazzo Sao Paulo Brazil 

出 版 物:《World Journal of Cardiovascular Diseases》 (心血管病(英文))

年 卷 期:2016年第6卷第10期

页      面:321-328页

学科分类:1002[医学-临床医学] 100201[医学-内科学(含:心血管病、血液病、呼吸系病、消化系病、内分泌与代谢病、肾病、风湿病、传染病)] 10[医学] 

主  题:Intra-Aortic Balloon Pumping Left Ventricular Dysfunction Coronary Artery Bypass Graft 

摘      要:Background: The intra-aortic balloon pumping (IABP) is the most used ventricular mechanical assist device. In recent years, the preoperative use in patients with severe ventricular dysfunction presents itself as a great benefic strategy to the postoperative recovery. This paper aim is to evaluate the IABP post-operative benefit in patients with severe ventricular dysfunction. Methods: From January 2011 to March 2016, 125 patients underwent a coronary artery bypass graft (CABG) with cardiopulmonary bypass and preoperative IABP in Teaching Hospital of the ABC Medical School and Hospital Estadual Mario Covas. The inclusion criteria were the presence of severe ischemic cardiomyopathy with left ventricular ejection fraction (LVEF) less than or equal to 40%, estimated by Doppler echocardiography using the Simpson method. The preoperative LVEF was 30.25% ± 8.53% and the diastolic diameter of the left ventricle (LVDD) 67.75 ± 16.37 mm. IABP was installed approximately 15 hours before the surgery. Results: The patients required the IABP for 2.4 ± 1.58 days, and vasoactive drugs, 4.8 ± 2.12 days. We performed 3.2 ± 1.9 grafts per patient and the total length of stay was 07 ± 5.52 days. Cardiopulmonary bypass time was 67 ± 10.95 minutes and anoxia time, 46.4 ± 10.06 minutes. Twelve patients (9.6%) had pneumonia and four (3.2%), atrial fibrillation. We observed a LVDD reduction to 63 ± 16.26 (p = 0.068) and LVEF enhancement to 36.50 ± 16.86 (p = 0.144). The data were analyzed statistically according to the Wilcoxon test. There were no deaths. Conclusion: The initial experience of the authors with the preoperative IABP in patients with severe left ventricular dysfunction suggests great benefit in post-operative recovery with im-provement of LVEF and reduction of LVDD.

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分