咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >Transient elastography: Kill t... 收藏

Transient elastography: Kill two birds with one stone?

Transient elastography: Kill two birds with one stone?

作     者:Grace Lai-Hung Wong 

作者机构:Department of Medicine and Therapeuticsand Institute of Digestive DiseaseThe Chinese University of Hong Kong 

出 版 物:《World Journal of Hepatology》 (世界肝病学杂志(英文版)(电子版))

年 卷 期:2013年第5卷第5期

页      面:264-274页

学科分类:1002[医学-临床医学] 100201[医学-内科学(含:心血管病、血液病、呼吸系病、消化系病、内分泌与代谢病、肾病、风湿病、传染病)] 10[医学] 

主  题:Biopsy Cirrhosis Fibrosis Hepatitis Fatty liver Steatosis of liver 

摘      要:Assessment of liver fibrosis and steatosis is crucial in chronic liver diseases in order to determine the prognosis, the need of treatment, as well as monitor disease progression and response to treatment. Liver biopsy is limited by its invasiveness and patient acceptability. Transient elastography (TE, Fibroscan ) is a non-invasive tool with satisfactory accuracy and reproducibility to estimate liver fibrosis and steatosis. TE has been well validated in major liver diseases including chronic hepatitis B and C, non-alcoholic fatty liver disease, alcoholic liver disease, primary biliary cirrhosis, and primary sclerosing cholangitis. As alanine aminotransferase (ALT) is one of the major confounding factors of liver stiffness in chronic hepatitis B, an ALT-based algorithm has been developed and higher liver stiffness measurements (LSM) cutoff values for different stages of liver fibrosis should be used in patients with elevated ALT levels up to 5 times of the upper limit of normal. Otherwise falsely-high LSM results up to cirrhotic range may occur during ALT flare. TE is also useful in predicting patient prognosis such as development of hepatocellular carcinoma (HCC), portal hypertension, post-operative complications in HCC patients, and also survival. Unfortunately, failed acquisition of TE is common in obese patients. Furthermore,obese patients may have higher LSM results even in the same stage of liver fibrosis. The new XL probe, a larger probe with lower ultrasound frequency and deeper penetration, increases the success rate of TE in obese patients. The median LSM value with XL probe was found to be lower than that by the conventional M probe, hence cutoff values approximately 1.2 to 1.3 kPa lower than those of M probe should be adopted. Recent studies revealed a novel ultrasonic controlled attenuation parameter (CAP) of the machine is a useful parameter to detect even low-grade steatosis noninvasively. CAP may also be used to quantify liver steatosis by applying d

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分