Wall-Attached Night Ventilation Combined with Phase Change Material Wallboard in Hot Summer:An Experimental Study on the Thermal Performance

Wall-Attached Night Ventilation Combined with Phase Change Material Wallboard in Hot Summer: An Experimental Study on the Thermal Performance

作     者:JI Wenhui YUAN Yanping LI Yajun YU Min JI Wenhui;YUAN Yanping;LI Yajun;YU Min

作者机构:School of Mechanical EngineeringSouthwest Jiaotong UniversityChengdu 610031China 

出 版 物:《Journal of Thermal Science》 (热科学学报(英文版))

年 卷 期:2022年第31卷第2期

页      面:318-331页

核心收录:

学科分类:08[工学] 0807[工学-动力工程及工程热物理] 081304[工学-建筑技术科学] 0813[工学-建筑学] 0802[工学-机械工程] 

基  金:the financial support of the National Key Research and Development Program of China(Grant No.2018YFC0705306) National Natural Science Foundation of China(No.52108096) Fundamental Research Funds for the Central Universities(No.2682020CX28) project from Key Lab.of Marine Power Engineering and Tech.authorized by MOT(No.KLMPET2020-04)。 

主  题:night ventilation wall-attached jet ventilation phase change material wallboard thermal performance 

摘      要:Night ventilation is regarded as a promising cooling strategy by storing night cooling in the thermal mass of the building.However,night ventilation performance in hot summer is restricted by the climatic limits.In this paper,we propose a new solution as the integration of wall-attached night ventilation(WANV)and phase change material wallboard(PCMW).The principle of the proposed system is to utilize the wall-attached jet ventilation to achieve forced convection and to adopt latent energy storage of PCMW to enlarge the energy storage density capabilities,and the coupling method is expected to improve the night ventilation performance.Comparative experiments were conducted to evaluate the thermal performance of the hybrid system by evaluating indoor temperature history,thermal comfort time and cooling efficiency.Due to the high thermal energy storage density capability of PCMW,it was found that the presence of PCMW has a negative influence on night cooling efficiency but still has a positive influence on the overall cooling effect.The proposed WANV combined with the PCMW system significantly increased the temperature decrease of room air and west wall inside surface during one hour s night ventilation by 94.97%and 67.74%,respectively,and reached an extension of 38.42%of indoor thermal comfort time.The results highlight the potential of WANV integration of PCMW to improve the thermal performance of night ventilation.

读者评论 与其他读者分享你的观点

用户名:未登录