Thermal test and numerical simulation of cooling stave with internal ribbed tube

作     者:Xun Xu Li-jun Wu Zhao-kuo Yuan Xun Xu;Li-jun Wu;Zhao-kuo Yuan

作者机构:Xinglin CollegeNantong UniversityNantong 226000JiangsuChina School of Mechanical EngineeringTongji UniversityShanghai 201804China 

出 版 物:《Journal of Iron and Steel Research International》 (Journal of Iron and Steel Research, International)

年 卷 期:2022年第29卷第8期

页      面:1194-1204页

核心收录:

学科分类:08[工学] 0815[工学-水利工程] 0801[工学-力学(可授工学、理学学位)] 

基  金:funded by the National Natural Science Foundation of China(51574179) Nantong Science and Technology Project(JC2019154) 

主  题:Cooling stave Internal ribbed tube Heat transfer Thermal test Numerical simulation 

摘      要:A new type of cooling stave with internal ribbed tube was proposed,and the heat transfer performance of the stave was studied by means of thermal test and numerical *** temperature of cooling stave was monitored in the conditions of furnace gas temperature of 200-700 C and cooling water velocity of 0.2-1.0 m/*** thermal test results show that the internal rib structure can form swirl in the water pipe and improve the cooling capacity of the cooling *** higher the furnace temperature or the lower the cooling water flow rate,the more obvious the advantage of the cooling stave with internal ribbed *** mathematical model of the cooling stave with internal ribbed tube was established by FLUENT software,and the influence of the internal rib structure parameters on the heat transfer performance of the cooling stave was *** is suggested that the parameters of the internal ribbed tube should be 4 ribs,1 mm in height,5-7 mm in width,and 20-30 mm in *** the same common working conditions of the cooling stave,the maximum temperature of the newly designed cooling stave with internal ribbed tube is reduced by 5.6%compared with that of common cooling stave with round *** water flow rate in the internal ribbed tube only needs 0.9 m/s to reach the cooling effect of 2 m/s in the common tube cooling stave,which can save 55%of *** case of water shortage accident of cooling stave,the maximum temperature of the cooling stave with internal ribbed tube is decreased by 22.4%compared with that of common round tube,which can effectively reduce the harm of water shortage and protect the cooling stave.

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分