咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >Evaluation of the Purification... 收藏

Evaluation of the Purification Performance of the Kossodo Wastewater Treatment Plant in Ouagadougou

Evaluation of the Purification Performance of the Kossodo Wastewater Treatment Plant in Ouagadougou

作     者:Bienvenue Joceline Sawadogo Martine Kone Rose Yamma Stéphane Nonet Philippe Walhain Roseline Kabore Toltama Sanou Théodore Nana Amado Ouedraogo H. Arsène Yonli Bienvenue Joceline Sawadogo;Martine Kone;Rose Yamma;Stéphane Nonet;Philippe Walhain;Roseline Kabore;Toltama Sanou;Théodore Nana;Amado Ouedraogo;H. Arsène Yonli

作者机构:National Centre for Scientific and Technological Research (NCSTR) Ouagadougou Burkina Faso UFR/SEA Joseph KI-ZERBO University Ouagadougou Burkina Faso Research and Expertise Center for Water (CEBEDEAU) Liege Belgium University of Liege-Start Tilman Liege Belgium National Office of Water and Sanitation (NOWS) Ouagadougou Burkina Faso 

出 版 物:《Journal of Environmental Protection》 (环境保护(英文))

年 卷 期:2021年第12卷第12期

页      面:1128-1143页

学科分类:083002[工学-环境工程] 0830[工学-环境科学与工程(可授工学、理学、农学学位)] 08[工学] 

主  题:Mixed Wastewater Natural Lagooning Nitrogen Phosphorus 

摘      要:The efficiency of a wastewater treatment system is classically measured by the quality of its discharge into the aquatic environment. This quality can only be achieved if certain aspects are taken into account, such as the design and operation of the system in place. The objective of the present work is to evaluate the purification performance of this system after 17 years of operation. It should be noted that the lagoon plant (WWTP) has a total of eight basins, three of which are anaerobic (ANA). The evaluation of the physicochemical and microbiological parameters in the anaerobic basins and in the maturation basins allowed us to note slightly basic pH values in the maturation basins (8.7 to 9.2) against values from 6.8 to 7.4 in the anaerobic basins. Also, the values in terms of organic and bacteriological pollution have also evolved. For COD and BOD5, we obtained respectively abatements of more than 73% for filtered COD, 55% for gross COD and 81% for BOD5 even if the residual concentrations do not respect the standards of wastewater discharge in our country. Also, the residual concentrations of ammonia nitrogen in the output effluents (on average 12.43 mg/L), do not meet the standard of discharge into surface waters of Burkina Faso (1.29 mg/L). Thus, nutrients such as nitrogen and phosphorus pollution have average abatement rates of 31% and 27% respectively. In sum, we can say that the lagoon system set up does not meet the requirements in terms of quality of discharges, which remains an environmental problem for the receiving environment.

读者评论 与其他读者分享你的观点