咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >Virtual nonenhanced abdominal ... 收藏

Virtual nonenhanced abdominal dual-energy MDCT:Analysis of image characteristics

虚拟非增强腹部双能量MDCT图像特征分析

作     者:Jacob Sosna Shmuel Mahgerefteh Liran Goshen Galit Kafri Galit Aviram Arye Blachar 

作者机构:Department of RadiologyHadassah-Hebrew University Medical CenterJerusalem 91120Israel Department of RadiologyBeth Israel Deaconess Medical CenterBostonMA 02215United States Philips HealthcareHaifa 31004Israel Department of RadiologyTel Aviv Sourasky Medical CenterSackler School of MedicineTel Aviv UniversityTel Aviv 64239Israel 

出 版 物:《World Journal of Radiology》 (世界放射学杂志(英文版)(电子版))

年 卷 期:2012年第4卷第4期

页      面:167-173页

学科分类:0831[工学-生物医学工程(可授工学、理学、医学学位)] 08[工学] 0836[工学-生物工程] 

主  题:Abdominal computed tomography Dual-energy computed tomography Pelvic computed tomography Virtual nonenhanced computed tomography 

摘      要:AIM: To evaluate abdominal and pelvic image characteristics and artifacts on virtual nonenhanced (VNE) images generated from contrast-enhanced dual-energy multidetector computed tomography (MDCT) studies. METHODS: Hadassah-Hebrew University Medical Institutional Review Board approval was obtained; 22 patients underwent clinically-indicated abdominal and pelvic single-source dual-energy MDCT (Philips Healthcare, Cleveland, OH, USA), pre- and post-IV administration of Omnipaque 300 contrast (100 cc). Various solid and vascular structures were evaluated. VNE images were generated from the portal contrast-enhanced phase using probabilistic separation. Contrast-enhanced-, regular nonenhanced (RNE)-, and VNE images were evaluated with a total of 1494 density measurements. The ratio of iodine contrast deletion was calculated. Visualization of calcifications, urinary tract stones, and image artifacts in VNE images were assessed. RESULTS: VNE images were successfully generated in all patients. Significant portal-phase iodine contrast deletion was seen in the kidney (61.7%), adrenal gland (55.3%), iliac artery (55.0%), aorta (51.6%), and spleen (34.5%). Contrast deletion was also significant in the right atrium (RA) (51.5%) and portal vein (39.3%), but insignificant in the iliac vein and inferior vena cava (IVC). Average post contrast-to-VNE HU differences were significant (P 0.05) in the: RA -135.3 (SD 121.8), aorta -114.1 (SD 48.5), iliac artery -104.6 (SD 53.7), kidney -30.3 (SD 34.9), spleen -9.2 (SD 8.8), and portal vein -7.7 (SD 13.2). Average VNE-to-RNE HU differences were significant in all organs but the prostate and subcutaneous fat: aorta 38.0 (SD 9.3), RA 37.8 (SD 16.1), portal vein 21.8 (SD 12.0), IVC 12.2 (SD 11.6), muscle 3.3 (SD 4.9), liver 5.7 (SD 6.4), spleen 22.3 (SD 9.8), kidney 40.5 (SD 6.8), and adrenal 20.7 (SD 13.5). On VNE images, 196/213 calcifications (92%) and 5/6 renal stones (84%) were visualized. Lytic-like artifacts in the vertebral bodies we

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分