摘      要:Harmonic cavities(HCs)are widely used in electron storage rings,mainly to increase the Touschek lifetime by lengthening *** have become critical components of almost all fourth-generation synchrotron light *** addition to the benefits of increasing the Touschek lifetime,they also affect the collective beam instabilities in electron storage ***,the influ-ence of HC settings on collective beam instabilities is still not well *** are typically designed to operate under so-called ideal lengthening conditions,which do not necessarily optimize the suppression of collective beam *** therefore extended earlier studies of col-lective beam instabilities to consider more general HC *** present preliminary studies and analyses of the influences of different HC settings on microwave and transverse mode-coupling instabilities.