Complications associated with energy-based devices during thyroidectomy from 2010–2020

Complications associated with energy-based devices during thyroidectomy from 2010–2020

作     者:Esther Lee Jane Y.Tong Luke J.Pasick Daniel A.Benito Arjun Joshi Punam G.Thakkar Joseph F.Goodman Esther Lee;Jane Y. Tong;Luke J. Pasick;Daniel A. Benito;Arjun Joshi;Punam G. Thakkar;Joseph F. Goodman

作者机构:Division of Otolaryngology-Head and Neck SurgeryGeorge Washington University School of Medicine& Health SciencesWashingtonDCUSA Western University of Health SciencesPomonaCAUSA Department of Otolaryngology-Head and Neck SurgeryDrexel University College of MedicinePhiladelphiaPAUSA Department of Otolaryngology-Head and Neck SurgeryUniversity of Miami Miller School of MedicineMiamiFLUSA 

出 版 物:《World Journal of Otorhinolaryngology-Head and Neck Surgery》 (世界耳鼻咽喉头颈外科杂志(英文))

年 卷 期:2023年第9卷第1期

页      面:35-44页

核心收录:

学科分类:1003[医学-口腔医学] 1002[医学-临床医学] 100210[医学-外科学(含:普外、骨外、泌尿外、胸心外、神外、整形、烧伤、野战外)] 10[医学] 

基  金:None 

主  题:Adverse events Harmonic LigaSure Manufacture and User Facility Device Experience Patient safety Quality Thunderbeat Thyroidectomy 

摘      要:Objective:Harmonic Focus(Ethicon,Johnson and Johnson,Cincinnati,OH,USA),LigaSure Small Jaw(Medtronic,Covidien Products,Minneapolis,MN,USA),and Thunderbeat Open Fine Jaw(Olympus,Japan)are electrosurgical instruments used widely in head and neck *** study aims to compare device malfunctions,adverse events to patients,operative injuries,and interventions related to Harmonic,LigaSure,and Thunderbeat use during ***:The US Food and Drug Administration s Manufacture and User Facility Device Experience(MAUDE)database was queried for adverse events associated with Harmonic,LigaSure,and Thunderbeat from January 2005 to August *** were extracted from reports pertaining to ***:Of the 620 adverse events extracted,394(63.5%)involved Harmonic,134(21.6%)LigaSure,and 92(14.8%)*** reported device malfunctions most frequently associated with Harmonic was damage to the blade(110(27.9%)),LigaSure was inappropriate function(47(43.1%)),Thunderbeat was damage to the tissue or Teflon pad(27(30.7%)),*** injury and incomplete hemostasis were the most commonly reported adverse *** operative injury reported most frequently when using Harmonic and LigaSure was burn *** operator injuries were reported with Thunderbeat ***:The most frequently reported device malfunctions were damage to the blade,inappropriate function,and damage to the tissue or Teflon *** most frequently reported adverse events to patients was a burn injury and incomplete *** aimed at improving physician education may help reduce adverse events attributed to improper use.