咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >Test of a ^(3)He neutron detec... 收藏

Test of a ^(3)He neutron detector readout electronics prototype for CSNS multipurpose physics neutron diffractometer

作     者:Xiao-guang Wu Yu-bin Zhao Hong Luo Jian-rong Zhou Liang Xiao Xiao-juan Zhou Bei-ju Guan Xing-cheng Tian Lin Zhu Xing-fen Jiang Zhi-jia Sun 

作者机构:State Key Laboratory of Particle Detection and ElectronicsInstitute of High Energy PhysicsChinese Academy of Sciences(CAS)Beijing 100049China University of Chinese Academy of Sciences(UCAS)Beijing 100049China Spallation Neutron Source Science CenterDongguan 523803China 

出 版 物:《Radiation Detection Technology and Methods》 (辐射探测技术与方法(英文))

年 卷 期:2021年第5卷第2期

页      面:200-206页

核心收录:

学科分类:07[理学] 0807[工学-动力工程及工程热物理] 0827[工学-核科学与技术] 0703[理学-化学] 070202[理学-粒子物理与原子核物理] 0702[理学-物理学] 0801[工学-力学(可授工学、理学学位)] 

基  金:the State Key Laboratory of Particle Detection and Electronics and supported by a grant from the Scientific Research Foundation of Advanced talents(innovation team)of DGUT(No.KCYCXPT2016004) 

主  题:CSNS MPI 3He tube Readout electronics prototype Functional and performance tests 

摘      要:Background Large areas of 3He neutron detector array and corresponding readout electronics are used in the MPI built at China Spallation Neutron Source(CSNS)to measure the position and flight time of scattered neutrons,and MPI has a high requirement for the position resolution of 3He neutron detector.A 3He neutron detector readout electronics prototype composed of two front-end boards and one digital readout board is designed to meet the above *** Testing the whole readout electronics system before its mass production to ensure it can run correctly and fulfill the functional and performance *** The test of the readout electronics prototype is implemented in the laboratory,and a signal generator is used to generate electronic signals instead of actual neutron *** position resolution test of the readout electronics prototype with 3He tubes is carried out in the No.20 beamline measurement room of *** and Conclusion The functional and performance tests in the laboratory state that the readout electronics prototype can fulfill the readout *** typical value of charge resolution is 0.85 fC;the integral nonlinearity of charge is 0.094%in the input charge range from 100 to 800 *** position resolution test result of the prototype with 3He tubes is better than the design requirement of 10 mm and also quite good compared with that of some other commercial *** tests provide a reliable basis for the mass production of the readout electronics prototype.

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分