咨询与建议

看过本文的还看了

相关文献

该作者的其他文献

文献详情 >Proximal tibial osteotomy for ... 收藏

Proximal tibial osteotomy for genu varum:Radiological evaluation of deformity correction with a plate vs external fixator

作     者:S Ali Ghasemi David T Zhang Austin Fragomen S Robert Rozbruch 

作者机构:Department of Orthopedic SurgeryHospital for Special SurgeryWeill Medical College of Cornell UniversityNew YorkNY 10021United States 

出 版 物:《World Journal of Orthopedics》 (世界骨科杂志(英文版))

年 卷 期:2021年第12卷第3期

页      面:140-151页

学科分类:0403[教育学-体育学] 1002[医学-临床医学] 10[医学] 

主  题:High tibial osteotomy External fixator Gradual correction Plate and screw Genu varum Radiological 

摘      要:BACKGROUND High tibial osteotomy(HTO)is a well-known procedure for the correction of knee varus.The purpose of this study was to compare the radiological results and accuracy of deformity correction performed using two different techniques:acute opening wedge correction using a plate and gradual correction with a monolateral external fixator.AIM To compare of the radiological results of two different techniques:acute opening wedge correction(a plate and screw)and gradual correction(external fixator).METHODS A total of 43 patients with plates and 36 patients with external fixators were included.All patients had moderate uniplanar varus deformities.We measured radiographic parameters,including the mechanical axis deviation(MAD),medial proximal tibial angle(MPTA),Caton-Deschamps Index(CDI),posterior proximal tibial angle,and joint line obliquity angle(JLOA).The accuracy of MAD correction was calculated based on a correction goal of neutral or overcorrection for medial compartment arthritis.RESULTS Demographics including age,body mass index,sex,and preoperative deformities were similar between the groups.The MAD significantly improved from 23.6 mm medial to the midline(SD=8.2 mm)to 6.9 mm lateral to the midline(SD=5.4 mm)(P0.001).The accuracy of MAD correction did not differ between the groups and was 96.1%(SD=8.1%)in the plate group and 98.2%(SD=5.2%)in the external fixator group(P=0.18).The MPTA significantly improved from 83.9°(SD=2.9°)to 90.9°(SD=3.3°)(P0.001),and the change was similar between the groups.Differences were noted in patella height,with a CDI change of-19.2%(SD=13.7%)and 3.1%(SD=8.0%)for the plate and external fixator groups,respectively(P0.001).The change in JLOA was 1.6 degrees(SD=1.1 degrees)and 0.9 degrees(SD=0.9 degrees)for the plate and external fixator groups,respectively(P=0.04).CONCLUSION Reliable correction of moderate varus alignment was achieved with both the acute opening wedge technique with a plate and the gradual monolateral external fixator technique.The patellar height decreased with the open wedge plate technique.Joint line obliquity decreased to a greater degree with the open wedge plate technique,perhaps as a result of medial collateral ligament release.The appropriate technique should be selected based on surgeon and patient preferences;however,external fixation may be a better choice when the preservation of patellar height is deemed important.

读者评论 与其他读者分享你的观点

用户名:未登录
我的评分