Branch Quality Control of Gas-Liquid Two-Phase Flow Using a Novel T-Junction Type Distributor
Branch Quality Control of Gas-Liquid Two-Phase Flow Using a Novel T-Junction Type Distributor作者机构:College of Pipeline and Civil EngineeringChina University of Petroleum
出 版 物:《Journal of Harbin Institute of Technology(New Series)》 (哈尔滨工业大学学报(英文版))
年 卷 期:2014年第21卷第4期
页 面:110-115页
核心收录:
学科分类:080704[工学-流体机械及工程] 08[工学] 0807[工学-动力工程及工程热物理]
基 金:Sponsored by the National Natural Science Foundation of China (Grant No.51006123) the Fundamental Research Funds for the Central Universities (Grant No.14CX05028A)
主 题:gas-liquid two-phase flow distributor phase splitting flow pattern quality control
摘 要:In order to eliminate mal-distribution and ensure the side arm to produce desirable gas quality a special distributor is proposed. The experimental distributor mainly consists of a straight through section,a gas extraction line,a liquid extraction line and a side arm branch. A gas orifice and a liquid orifice are mounted at the gas and liquid extraction line respectively to control the outlet gas quality. The diameter of the liquid orifice was set to 2. 50 mm and three gas orifices with different size( dG= 2. 65,5. 00,10. 00 mm) were tested. The experiments were carried out at an air-water two-phase flow loop. The gas superficial velocity ranged from 6. 0 to 20. 0 m /s and the liquid superficial velocity was in the range of 0. 02- 0. 18 m /s. Flow patterns such as wave flow,slug flow and annular flow were observed. The gas quality of the side arm branch was found mainly determined by the flow area ratio of the gas orifice to the liquid orifice and independent of gas and liquid superficial velocity,flow patterns and extraction flux.