Safety and efficacy of stent-assisted coiling for acutely ruptured wide-necked intracranial aneurysms:comparison of LVIS stents with laser-cut stents
Safety and efficacy of stent-assisted coiling for acutely ruptured wide-necked intracranial aneurysms: comparison of LVIS stents with laser-cut stents作者机构:Department of NeurosurgeryGeneral Hospital of Southern Theatre Command of PLA111 Liuhua RoadGuangzhou 510010China Department of NeurosurgeryChanghai HospitalNaval Medical University168 Changhai RoadShanghai 200433China
出 版 物:《Chinese Neurosurgical Journal》 (中华神经外科杂志(英文))
年 卷 期:2021年第7卷第2期
页 面:116-125页
核心收录:
学科分类:1002[医学-临床医学] 100204[医学-神经病学] 10[医学]
基 金:This work was supported by the National Key Research and Development Program of China(grant no.: 2016YFC1300703) National Natural Science Foundation of China(grant no.: 81701136, 81571126)
主 题:Ruptured intracranial aneurysm LVIS stent Laser-cut stent Propensity score matching
摘 要:Background:To compare the safety and efficacy of LVIS stent-assisted coiling with those of laser-cut stent-assisted coiling for the treatment of acutely ruptured wide-necked intracranial ***:Patients with acutely ruptured wide-necked intracranial aneurysms treated with LVIS stent-assisted coiling(LVIS stent group)and laser-cut stent-assisted coiling(laser-cut stent group)were retrospectively reviewed from January 2014 to December *** score matching was used to adjust for potential differences in age,sex,aneurysm location,aneurysm size,neck width,Hunt-Hess grade,and modified Fisher *** procedure-related complications and clinical and angiographic follow-up outcomes were *** and multivariate analyses were performed to determine the associations between procedure-related complications and potential risk ***:A total of 142 patients who underwent LVIS stent-assisted coiling and 93 patients who underwent laser-cut stent-assisted coiling were enrolled after 1:2 propensity score *** angiographic follow-up outcomes showed that the LVIS stent group had a slightly higher complete occlusion rate and lower recurrence rate than the laser-cut stent group(92.7%vs 80.6%;3.7%vs 9.7%,P=0.078).The clinical outcomes at discharge and follow-up between the two groups demonstrated no significant differences(P=0.495 and P=0.875,respectively).The rates of intraprocedural thrombosis,postprocedural thrombosis,postoperative early rebleeding,and procedure-related death were 0.7%(1/142),1.4%(2/142),2.8%(4/142),and 2.1%(3/142)in the LVIS stent group,respectively,and 4.3%(4/93),2.2%(2/93),1.1%(1/93),and 3.2%(3/93)in the laser-cut stent group,respectively(P=0.082,0.649,0.651,and 0.683).Nevertheless,the rates of overall procedure-related complications and intraprocedural rupture in the LVIS stent group were significantly lower than those in the laser-cut stent group(5.6%vs 14.0%,P=0.028;0.7%vs 6.5%,P=0.016).Multivariate an